Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. bras. ortop ; 57(3): 502-510, May-June 2022. tab, graf
Article in English | LILACS | ID: biblio-1388008

ABSTRACT

Abstract Objective The Schatzker classification is the most used for tibial plateau fractures. Kfuri et al.12 reviewed Schatzker's initial classification describing in more detail the involvement of the tibial plateau in the coronal plane, allowing a better understanding of the fracture pattern and a more accurate surgical planning. The objectives of the present study are to evaluate the interobserver agreement of these classifications and to evaluate the influence of the experience of the observer on the reproducibility of the instruments. Methods An observational and retrospective study was conducted by evaluating the radiological study of 20 adult individuals with tibial plateau fractures, including radiographs and computed tomography (CT). The fractures were classified once by 34 examiners with varied experience (24 specialists and 10 residents in Orthopedics and Traumatology), according to the Schatzker classification and to the modification proposed by Kfuri. The Fleiss Kappa index was used to verify interobserver agreement. Results The interobserver agreement index was considered moderate for the Schatzker classification (κ = 0.46) and mild for the Kfuri modification (κ = 0.30). The Schatzker classification showed moderate agreement, with κ = 0.52 for residents and κ = 0.45 among specialists. The Kfuri classification showed mild agreement, with Kappa values for residents and specialists of 0.39 and 0.28, respectively. Conclusion The Schatzker classification and the classification modified by Kfuri presented moderate and mild interobserver agreement, respectively. In addition, the residents presented higher agreement than the specialists for the two systems studied.


Resumo Objetivo A classificação de Schatzker é a mais utilizada para as fraturas do planalto tibial. Kfuri et al.12 revisaram a classificação inicial de Schatzker descrevendo com mais detalhes o envolvimento do planalto tibial no plano coronal, permitindo uma melhor compreensão do padrão de fratura e um planejamento cirúrgico mais acurado. Os objetivos do presente estudo são avaliar a concordância inter-observador dessas classificações e avaliar a influência da experiência dos observadores na reprodutibilidade dos instrumentos. Métodos Foi realizado um estudo observacional e retrospectivo, por meio da avaliação do estudo radiológico de 20 indivíduos adultos com fraturas do planalto tibial, incluindo radiografias e tomografia computadorizada (TC). As fraturas foram classificadas 1 vez por 34 examinadores com experiência variada (24 especialistas e 10 residentes em Ortopedia e Traumatologia), de acordo com a classificação de Schatzker e com a modificação proposta por Kfuri. O índice Kappa de Fleiss foi usado para verificar a concordância interobservadores. Resultados O índice de concordância inter-observador foi considerado moderado paraa classificação de Schatzker (κ = 0,46) e leve para a modificação de Kfuri (κ = 0,30). A classificação de Schatzker apresentou concordância moderada, com κ = 0,52 para residentes e κ = 0,45 entre os especialistas. A classificação de Kfuri apresentou concordância leve com valores de Kappa para residentes e especialistas de 0,39 e 0,28, respectivamente. Conclusão A classificação de Schatzker e a classificação modificada por Kfuri apresentaram concordância interobservadores moderada e leve, respectivamente. Além disso, os residentes apresentaram concordâncias superiores aos especialistas para os dois sistemas estudados.


Subject(s)
Humans , Adult , Tibial Fractures , Reproducibility of Results , Knee Injuries , Knee Joint/surgery
2.
Rev. bras. ortop ; 56(3): 372-378, May-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1288677

ABSTRACT

Abstract Objective The present study aims to analyze the intra- and interobserver reproducibility of the Lauge-Hansen, Danis-Weber, and Arbeitsgemeinschaft für Osteosynthesefragen (AO) classifications for ankle fractures, and the influence of evaluators training stage in these assessments. Methods Anteroposterior (AP), lateral and true AP radiographs from 30 patients with ankle fractures were selected. All images were evaluated by 11 evaluators at different stages of professional training (5 residents and 6 orthopedic surgeons), at 2 different times. Intra- and interobserver agreement was analyzed using the weighted Kappa coefficient. Student t-tests for paired samples were applied to detect significant differences in the degree of interobserver agreement between instruments. Results Intraobserver analysis alone had a significant agreement in all classifications. Moderate to excellent interobserver agreement was highly significant (p ≤ 0.0001) for the Danis-Weber classification. The Danis-Weber classification showed, on average, a significantly higher degree of agreement than the remaining classification systems (p ≤ 0.0001). Conclusion The Danis-Weber classification presented the highest reproducibility among instruments and the evaluator's little experience had no negative influence on the reproducibility of ankle fracture classifications. Level of Evidence II, Diagnostic Studies - Investigating a Diagnostic Test.


Resumo Objetivo Avaliar a reprodutibilidade intra- e interobservador das classificações de Lauge-Hansen, Danis-Weber e Arbeitsgemeinschaft für Osteosynthesefragen (AO) para as fraturas de tornozelo, e a influência do estágio de formação dos participantes na avaliação. Métodos Foram selecionadas radiografias de 30 pacientes com fratura de tornozelo nas incidências anteroposterior (AP), perfil e AP verdadeiro. Todas as imagens foram avaliadas por 11 participantes em diferentes estágios de formação profissional (cinco residentes e seis cirurgiões ortopédicos), em dois momentos distintos. Analisou-se a concordância inter- e intraobservador por meio do coeficiente Kappa ponderado. O teste t de Student para amostras pareadas foi aplicado para verificar se havia diferença significativa no grau de concordância interobservador entre os instrumentos. Resultado Observou-se que existe concordância significativa em todas as classificações quando da análise intraobservador isolada. Existe concordância interobservador altamente significativa de grau moderado a ótimo na classificação de Danis-Weber (p ≤ 0,0001). A classificação de Danis-Weber apresentou, em média, grau de concordância significativamente maior que as outras classificações (p ≤ 0,0001). Conclusão A classificação de Danis-Weber se mostrou a mais reprodutiva entre os instrumentos avaliados, e a pouca experiência do avaliador não influencia negativamente a reprodutibilidade das classificações das fraturas do tornozelo. Nível de Evidência II, Estudos Diagnósticos - Investigação de um Exame para Diagnóstico.


Subject(s)
Humans , Reproducibility of Results , Diagnostic Tests, Routine , Fractures, Bone , Ankle Fractures/classification , Orthopedic Surgeons
3.
Rev. bras. ortop ; 56(2): 251-255, Apr.-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1251334

ABSTRACT

Abstract Objective The present study aims to identify the energy required for synthetic proximal femoral fracture after removal of three implant types: cannulated screws, dynamic hip screws (DHS), and proximal femoral nail (PFN). Methods Twenty-five synthetic proximal femur bones were used: 10 were kept intact as the control group (CG), 5 were submitted to the placement and removal of 3 cannulated screws in an inverted triangle configuration (CSG), 5 were submitted to the placement and removal of a dynamic compression screw (DHSG), and 5 were submitted to the placement and removal of a proximal femur nail (PFNG). All samples were biomechanically analyzed simulating a fall on the greater trochanter using a servo-hydraulic machine to determine the energy (in Joules [J]) required for fracture. Results All samples presented basicervical fractures. The energy required for fracture was 7.1 J, 6.6 J, 6 J, and 6.7 J for the CG, CSG, DHSG and PFNG, respectively. There was no statistically significant difference (considering a 95% confidence interval) in energy among the study groups (p = 0.34). Conclusion There was no statistically significant difference in the energy required to cause a synthetic proximal femoral fracture after removing all three implant types and simulating a fall over the greater trochanter.


Resumo Objetivo Identificar a energia necessária para ocorrência de fratura do fêmur proximal em osso sintético após retirada de três modelos de implantes: parafusos canulados, parafuso dinâmico do quadril (dynamic hip screw-DHS) e haste femoral proximal (proximal femoral nail-PFN). Métodos Foram utilizados 25 modelos de ossos sintéticos da extremidade proximal do fêmur: 10 unidades de grupo controle (GC), 5 unidades após colocação e retirada de 3 parafusos canulados colocados em configuração de triângulo invertido (GPC), 5 unidades após colocação e retirada do parafuso de compressão dinâmico (GDHS), e 5 unidades após colocação e retirada da haste de fêmur proximal (GPFN). Uma análise biomecânica foi realizada em todas as amostras simulando uma queda sobre o grande trocânter utilizando uma máquina servo-hidráulica com o objetivo de verificar a energia (em Joules [J]) necessária até a ocorrência de fratura nos diferentes grupos. Resultados Todos os grupos apresentaram fratura basocervical. Os grupos GC, GPC, GDHS e GPFN apresentaram, respectivamente, valores de 7.1J, 6.6J, 6J e 6.7J de energia até ocorrência da fratura. Não houve diferença estatisticamente significativa (intervalo de confiança de 95%) na energia entre os grupos de estudo (p = 0,34). Conclusão Não houve diferença estatisticamente significativa nos valores de energia necessária para ocorrência de fratura da extremidade proximal do fêmur após a retirada de três tipos de implantes utilizando modelos sintéticos simulando queda sobre o grande trocânter.


Subject(s)
Case-Control Studies , Device Removal , Fractures, Bone , Fracture Fixation , Hip/surgery , Hip Fractures
SELECTION OF CITATIONS
SEARCH DETAIL